« Book Book » All
Books

Mechanical Engineers' Handbook, Instrumentation, Systems, Controls, and MEMS
by: Myer Kutz (Editor) AMAZON multi-meters discounts
AMAZON oscilloscope discounts
Topics include:
CLICK
HERE for more info and price
The updated Revision of the Bestseller-;In a more Useful Format! Mechanical Engineers' Handbook has a long tradition as a single resource of valuable information related to specialty areas in the diverse industries and job functions in which mechanical engineers work. This Third Edition , the most aggressive revision to date, goes beyond the straight data, formulas, and calculations provided in other handbooks and focuses on authoritative discussions, real-world examples, and insightful analyses while covering more topics that in previous editions. Book 2: Instrumentation, Systems, Controls, and MEMS is comprised of two major parts, conveniently put together because feedback control systems require measurement transducers. The first part covers instrumentation, including transducer design, strain gages, flow meters, digital integrated circuits, and issues involved in processing transducer signals and acquiring and displaying data. The second part addresses systems and control, including: Control system design, analysis, and performance modification Design of servoactuators, controllers, and general-purpose control devices New departures in mechanical engineering, including neural networks, mechatronics, and MEMS
About the Author
MYER KUTZ is founder and President of Myer Kutz Associates, Inc., a publishing and information services consulting firm.
CONTENTS
Preface
Vision Statement
Contributors
PART 1: INSTRUMENTATION
1. Instrument Statics (Jerry Lee Hall, Sriram Sundararajan, and Mahmood Naim)
2. Input and Output Characteristics (Adam C. Bell)
3. Bridge Transducers (Patrick L. Walter)
4. Measurements (E. L. Hixson and E. A. Ripperger)
5. Temperature and Flow Transducers (Robert J. Moffat)
6. Signal Processing (John Turnbull)
7. Data Acquisition and Display Systems (Philip C. Milliman)
8. Digital Integrated Circuits: A Practical Application (Todd Rhoad and Keith Folken)
PART 2: SYSTEMS, CONTROLS, AND MEMS
9. Systems Engineering: Analysis, Design, and Information Processing for Analysis and Design (Andrew P. Sage)
10. Mathematical Models of Dynamic Physical Systems (K. Preston White, Jr.)
11. Basic Control Systems Design (William J. Palm III)
12. Closed-Loop Control System Analysis (Suhada Jayasuriya)
13. Control System Performance Modification (Suhada Jayasuriya)
14. Servoactuators for Closed-Loop Control (Karl N. Reid and Syed Hamid)
15. Controller Design (Thomas Peter Neal)
16. General-Purpose Control Devices (James H. Christensen, Robert J. Kretschmann, Sujeet Chand, and Kazuhiko Yokoyama)
17. State-Space Methods for Dynamic Systems Analysis (Krishnaswamy Srinivasan)
18. Control System Design Using State-Space Methods (Krishnaswamy Srinivasan)
19. Neural Networks in Feedback Control Systems (F. L. Lewis and Shuzhi Sam Ge)
20. Mechatronics (Shane Farritor)
21. Introduction to Microelectromechanical Systems (MEMS): Design and Application (M. E. Zaghloul)
Index
Reviews:
|