| Home |
Contents1 The Basics of Integrated Circuits 2 General Purpose ICs (Arrays) 3 Op-Amps 8 Electric Motor Speed Controllers 9 Filters 10 Introducing Digital Circuits Introduction![]() Integrated Circuits (or ICs) are the building blocks from which modern electronic circuits are assembled. They save a lot of time in construction and give better performance than similar circuits built from separate components and, above all, are incredibly space saving. In these respects they are a big step ahead of single transistors and have made it easier for amateur constructors--as well as professionals--to build working circuits. There are thousands of different types of ICs, each of which may be adaptable to many different working circuits (although some of the more complex ones are designed with a limited range of application). This can be quite bewildering, especially knowing how and where to start. However, from the point of view of using ICs and putting them to work, there is no need at all to know the actual circuits they contain--merely what type of circuit they contain and how their leads or pins are connected to other components to complete a working circuit. That is what this guide is about. It explains and "classifies" integrated circuits in simple terms. It covers the various ways in which the simplest ICs--op-amps--can be worked and describes a whole range of working circuits based on selected--and inexpensive--integrated circuits. In this revised edition, several new projects have been added, some using recently developed ICs. All in all, this guide features 117 different working projects you can build. In fact it is really a basic -- and essentially practical -- "course" on understanding and using integrated circuits. ----------- This guide is based on the 1986 TAB book "117 Practical IC Projects You Can Build " 117 PRACTICAL IC PROJECTS YOU CAN BUILD R.H. WARRING and DELTON T. HORN TAB BOOKS Inc. Blue Ridge Summit, PA 17214, USA ----------- Other Bestsellers From TAB THE LINEAR IC HANDBOOK--Morley Far more than a replacement for manufacturers' data books. The Linear IC Handbook covers linear IC offerings from all the major manufacturers-complete with specifications, data sheet parameters, and price information-along with technological background on linear ICs. It gives you instant access to data on how linear ICs are fabricated, how they work, what types are avail able, and techniques for designing them. 624 pp., 366 illus. 6" x 9". Hard $49.50. Book No. 2672 7 THE 555 IC PROJECT BOOK -- Traister Now, with this exceptionally well-documented project guide, you can begin to use the 555 timer IC in a variety of useful projects that are both easy and fun to put together. From an IC metronome to a ten-second timer and even an electronic organ, this is an exciting collection of 33 different projects that even a novice at electronics can make easily, inexpensively, and in only a few hours time. Most important it provides the know-how to start you designing your own original 555 IC projects to suit your own special needs. 224 pp., 110 illus. Paper $11.95 Hard $18.95 Book No. 1996 THE ENCYCLOPEDIA OF ELECTRONIC CIRCUITS -- Graf Here's the electronics hobbyist's and technician's dream treasury of analog and digital circuits-nearly 100 circuit categories over 1,200 individual circuits designed for long-lasting applications potential. Adding even more to the value of this resource is the exhaustively thorough index which gives you instant access to exactly the circuits you need each and every time! 768 pp., 1,782 illus. 7" x 10". Paper $29.95 Book No. 1938 . BASIC INTEGRATED CIRCUITS -- Marks With the step-by-step guidance provided by electronics design ex pert Myles Marks, anyone with basic electronics know-how can design and build almost any type of modern IC device for almost any application imaginable! In fact, this is the ideal sourcebook for every hobbyist or experimenter who wants to expand his digital electronics knowledge and begin exploring the fascinating new possibilities offered by today's IC technology. 432 pp., 319 illus. Paper $16.95 Hard $26.95 Book No. 2609 1_-J 101 SOUND, LIGHT AND POWER IC PROJECT -- Shoemaker At last! Here's an IC project guide that doesn't stop with how and why ICs function ... it goes one step further to give you hands-on experience in the interfacing of integrated circuits to solve real-world problems. Projects include sound control circuits such as alarms and intercoms; light control projects from photoflash slave to a monitor/alarm; power control units and much more! 384 pp., 135 illus. Paper $16.95 Hard $24.95 Book No. 2604 DESIGNING IC CIRCUITS... WITH EXPERIMENTS--Horn With this excellent sourcebook as your guide, you'll be able to get started in the designing of your own practical circuits using op amps, 555 timers, voltage regulators, linear ICs, digital ICs, and other commonly available IC devices. It's crammed with practical design and construction tips and hints that are guar anteed to save you time, effort, and frustration no matter what your IC application needs. 364 pp., 397 illus. Paper $16.95 Hard $24.95 Book No. 1925 Other Bestsellers From TAB TRANSISTOR CIRCUIT DESIGN--with Experiments; Horn Here it is! The electronics project guide that you've been asking for a practical introduction to transistor circuit design and construction! Exceptionally easy-to-follow and overflowing with unique and practical projects complete with detailed circuit descriptions and schematics diagrams. Hobbyists and experimenters will find it especially valuable for its wealth of ex ample circuits and project plans and it's an essential guide for anyone who wants to fully understand the design and applications potential of transistor circuitry! 434 pp., 286 illus. Paper $14.95 Book No. 1875 THE MASTER IC COOKBOOK; Hallmark "Use-it-now" data on every IC family and function--CMOS and TTL 4000-- and 7400-series digital ICs, exotic CMOS, and linear ICs! It's a ONE-STOP SOURCE of descriptions, pinouts, and absolute maximum ratings for all classifications of ICs. Covers logic diagrams, power dissipation, propagation de lay time (or maximum clock frequency for flip-flops, counters, and registers), truth tables and more! Includes IC circuits you can build! 476 pp., 742 illus. Paper $16.95 Book No. 1199 BASIC INTEGRATED CIRCUIT THEORY AND PROJECTS-- Adams Here's the ideal guide for any one who wants to learn how integrated circuits work and who wants to begin using both analog and digital ICs in practical, working applications! Absolutely no advanced math or science background is needed, because the author has broken down IC theory into easily digestible segments, complete with applications data and 24 useful projects that provide you with hands on use experience. You can build a NAND gate, series NAND gates, a wired AND gate, a NOR gate, or a LM324 op amp amplifier. 266 pp., 295 illus. Paper $11.95 Book No. 1699 MASTER HANDBOOK OF 1001 PRACTICAL ELECTRONIC CIRCUITS The ideal schematic source book of IC and transistor circuits for practically anything and every thing-with ALL the data needed to put them to work ... each circuit diagram has every component care fully labeled, and every schematic has all the facts you need to con struct exactly the type of circuit you need! Includes an ultra-complete 22-page index, plus appendix of IC substitutions. 602 pp., over 1,250 illus. Paper $19.95 Book No. 800. Look for these and other TAB books at your local bookstore. TAB BOOKS Inc. P.O. Box 40 Blue Ridge Summit. PA 17214 Send for FREE TAB catalog describing over 1200 current titles in print. ++++++++++ FROM REAR COVER OF BOOK: 117 Practical IC Projects You Can Build R. H. Warring and Delton T. Horn Dozens of fully tested, ready-to-build circuits you can put together from readily available, low-cost ICs! Here is a collection of some of the most practical analog and digital integrated circuit devices available anywhere! Using the most up-to-date technology and IC circuitry, Warring and Horn have given you everything you need to build an amazing array of fully tested electronics devices ranging from an audio mixer and a signal splitter to a tape deck amplifier and a top octave generator organ! A total of 117 IC circuits are included in this single sourcebook! You'll find full explanations and classification of common ICs (including several new and advanced ICs) given in simple, easy-to-follow terms. And you'll learn how to put these inexpensive and readily avail able ICs to work in an amazing range of practical applications. Covered are op amps-the workhorse among all ICs, audio amplifiers, complete radio circuits, multivibrators, voltage regulators, electric mo tor speed controllers, filters, digital circuits, and other types of circuits. Full details on safe and efficient construction practices have also been included-important for the novice and a highly useful refresher course for more experienced hobbyists as well. The main thrust of the guide, however, is devoted to actual projects. Each one includes working diagrams and schematics to make construction of your projects as simple and error-free as possible. Best of all, every one of the included IC devices has been tested and proven so you know it will function when properly completed. Just a sampling of the devices you can build includes: an IC radio, a variable frequency square wave generator, a sine wave oscillator, a stereo amplifier, a magnetic cartridge preamp, a programmable monostable multivibrator, a series of circuits that when put together form a complete electronic organ, a quartz crystal clock circuit and alarm, a car theft alarm . . .and the list goes on and on! R. H. Warring and Delton T. Horn both have many years of experience as electronics hobbyists and professionals. Warring's previous books for TAB include Electronic Components Handbook for Circuit Designers. Among Horn's most popular TAB titles is Designing IC Circuits . . . with Experiments. TAB TAB BOOKS Inc. Blue Ridge Summit, Pa. 17214 Send for FREE TAB Catalog describing over 1200 current titles in print. FPT $10.95 ISBN 0-8306-2645-X PRICES HIGHER IN CANADA 1060-1186
|
| | NEXT | Guide Index | HOME |